Audiometer Calibration Equipment for Audiology Testing
Release time:2026.05.11 Views:14

Accurate audiometer calibration is essential for ensuring reliable hearing test results and maintaining compliance with international acoustic standards. Aihua Instruments provides professional audiometer calibration equipment, including sound calibrators, ear simulators, and acoustic couplers, designed for audiology laboratories, hearing aid manufacturers, hospitals, and acoustic testing institutions.        

Why Audiometer Calibration Matters

 Audiometers must be calibrated regularly to ensure accurate sound pressure levels and frequency response during hearing tests. Improper calibration can affect diagnostic accuracy and lead to unreliable hearing assessment results. Professional calibration equipment helps laboratories and medical institutions maintain compliance with IEC and ISO standards.        

Key Application Areas

Audiometer Verification and Calibration

Verify and calibrate audiometers to ensure accurate hearing threshold measurements and compliance with international acoustic standards.        

Headphone and Insert Earphone Testing

 Measure and evaluate the acoustic performance of supra-aural, circumaural, and insert earphones used in audiometric systems.  

Earphone Testing.png

  

Hearing Aid and Audiology Laboratory Testing

Support hearing aid development, audiology research, and laboratory acoustic measurements with precision ear simulators and acoustic couplers.        

Hearing Aid Testing

Applicable Standards

StandardDescription
IEC 60942Sound calibrator performance requirements
IEC 60318-1Ear simulator for supra-aural and circumaural earphones
IEC 60318-3Acoustic coupler for audiometric earphones
IEC 60318-4Occluded-ear simulator for inserting earphones

Recommended Products

   Aihua Instruments provides professional audiometer calibration equipment designed for precise acoustic verification and hearing device testing.        

AWA6221A Sound Calibrator Class 1

Model AWA6221A sound calibrator complies with IEC 60942 Class 1 requirements and provides stable and accurate acoustic calibration performance.

  • IEC 60942 Class 1 compliant

  • 94 dB and 114 dB output at 1000Hz

  • Stable sound negative feedback compression technology

  • Suitable for audiometer and sound level meter calibration

               View Details →            
AWA6221A Sound Calibrator
AWA6160 Ear Simulator

AWA6160 Ear Simulator (IEC 60318-1)

The AWA6160 ear simulator complies with IEC 60318-1:2009 and is designed for testing supra-aural and circumaural audiometric earphones.

  • IEC 60318-1:2009 compliant

  • Suitable for Radio Ear DD65V2 earphones

  • Compatible with Sennheiser HDA280

  • Ideal for audiometer calibration laboratories

               View Details →            

AWA6162 Ear Simulator (IEC60318-4)

The AWA6162 occluded-ear simulator is designed for insert earphone testing and audiometric calibration applications.

  • IEC60318-4:2010 compliant

  • Suitable for IP30 insert earphones

  • Compatible with ER-3A insert earphones

  • Professional insert earphone acoustic testing solution

               View Details →            
AWA6162 Ear Simulator
AWA6163A Acoustic Coupler

AWA6163A Acoustic Coupler (IEC60318-3)

The AWA6163A acoustic coupler complies with IEC60318-3:2014 and is suitable for audiometric headphone calibration and acoustic verification.

  • IEC60318-3:2014 compliant

  • Compatible with Beyer DT48 and TDH39 earphones

  • Supports Sennheiser HAD 280 and RadioEar DD45

  • Designed for professional audiology testing systems

               View Details →            

Frequently Asked Questions

What is audiometer calibration?

Audiometer calibration is the process of verifying and adjusting the output levels and frequency response of audiometers to ensure accurate hearing test results.

Why are ear simulators used in audiometer calibration?

Ear simulators replicate the acoustic impedance of the human ear and are used to accurately measure the sound pressure produced by audiometric earphones.

Which standards apply to audiometer calibration equipment?

Common standards include IEC 60942 for sound calibrators and IEC 60318 series standards for ear simulators and acoustic couplers.

How often should audiometers be calibrated?

Audiometers are typically calibrated annually, although daily listening checks and routine verification are also recommended.

Need Professional Audiometer Calibration Solutions?

Contact Aihua Instruments for professional product recommendations and calibration support.