Accurate audiometer calibration is essential for ensuring reliable hearing test results and maintaining compliance with international acoustic standards. Aihua Instruments provides professional audiometer calibration equipment, including sound calibrators, ear simulators, and acoustic couplers, designed for audiology laboratories, hearing aid manufacturers, hospitals, and acoustic testing institutions.
Audiometers must be calibrated regularly to ensure accurate sound pressure levels and frequency response during hearing tests. Improper calibration can affect diagnostic accuracy and lead to unreliable hearing assessment results. Professional calibration equipment helps laboratories and medical institutions maintain compliance with IEC and ISO standards.
Verify and calibrate audiometers to ensure accurate hearing threshold measurements and compliance with international acoustic standards.
Measure and evaluate the acoustic performance of supra-aural, circumaural, and insert earphones used in audiometric systems.

Support hearing aid development, audiology research, and laboratory acoustic measurements with precision ear simulators and acoustic couplers.

| Standard | Description |
| IEC 60942 | Sound calibrator performance requirements |
| IEC 60318-1 | Ear simulator for supra-aural and circumaural earphones |
| IEC 60318-3 | Acoustic coupler for audiometric earphones |
| IEC 60318-4 | Occluded-ear simulator for inserting earphones |
Aihua Instruments provides professional audiometer calibration equipment designed for precise acoustic verification and hearing device testing.
Model AWA6221A sound calibrator complies with IEC 60942 Class 1 requirements and provides stable and accurate acoustic calibration performance.
IEC 60942 Class 1 compliant
94 dB and 114 dB output at 1000Hz
Stable sound negative feedback compression technology
Suitable for audiometer and sound level meter calibration


The AWA6160 ear simulator complies with IEC 60318-1:2009 and is designed for testing supra-aural and circumaural audiometric earphones.
IEC 60318-1:2009 compliant
Suitable for Radio Ear DD65V2 earphones
Compatible with Sennheiser HDA280
Ideal for audiometer calibration laboratories
The AWA6162 occluded-ear simulator is designed for insert earphone testing and audiometric calibration applications.
IEC60318-4:2010 compliant
Suitable for IP30 insert earphones
Compatible with ER-3A insert earphones
Professional insert earphone acoustic testing solution


The AWA6163A acoustic coupler complies with IEC60318-3:2014 and is suitable for audiometric headphone calibration and acoustic verification.
IEC60318-3:2014 compliant
Compatible with Beyer DT48 and TDH39 earphones
Supports Sennheiser HAD 280 and RadioEar DD45
Designed for professional audiology testing systems
Audiometer calibration is the process of verifying and adjusting the output levels and frequency response of audiometers to ensure accurate hearing test results.
Ear simulators replicate the acoustic impedance of the human ear and are used to accurately measure the sound pressure produced by audiometric earphones.
Common standards include IEC 60942 for sound calibrators and IEC 60318 series standards for ear simulators and acoustic couplers.
Audiometers are typically calibrated annually, although daily listening checks and routine verification are also recommended.