Construction Vibration
Construction Vibration
Piling, blasting, demolition and compaction all send short, high-energy shocks into the ground — the kind that trigger damage claims from the building next door. Measure it before, during and after the work, and the claim has an answer.
-
VLeq,T
The time-averaged vibration level typically used to characterize exposure over a monitoring period, not a single pass-by event
-
2
Percentile levels that describe how often a given vibration level was exceeded — key to separating background from event-driven vibration
-
2
Distinct concerns to evaluate separately — human perception and annoyance, and the far lower thresholds that apply to sensitive equipment or heritage structures
Construction Vibration Is an Event, Not a Trend
-
Baseline & Ongoing Structural Monitoring
Percentile-based, time-averaged tracking (VLeq,T, VL5–VL95) at the nearest affected structure, run from before work starts through to completion, for both human-response and structural-risk records.
AWA6257A Environmental Vibration Analyzer -
Daily Spot-Checks During Active Operations
Quick, one-key-switching readings at the nearest structure before and after each pile, blast or demolition sequence, to confirm the day's activity is running within the agreed trigger level.
YT3001A Handheld Multi-Parameter Vibration Meter -
Protecting Sensitive & Heritage Structures
Older masonry, heritage buildings and vibration-sensitive equipment near the site often carry a far lower damage threshold, calling for a wider dynamic range and a more sensitive sensor to catch it early.
YT3001B High-Sensitivity Multi-Parameter Vibration Meter
-
Step 1 Survey & CalibrateRecord a baseline condition at nearby structures before work starts, and field-check every instrument against a vibration calibrator first.
-
Step 2 Set Trigger LevelsAgree the alert and action levels with the contract, permit, or affected party — these are what every reading during the work gets compared against.
-
Step 3 Monitor the WorksTrack each significant event — a pile strike, a blast, a demolition impact — against those levels for the duration of the activity.
-
Step 4 Verify & Close OutRun a post-construction check at the same points as the baseline survey, closing the record with a clear before-and-after comparison.
-
Common Questions About Construction Vibration
-
1. How is construction vibration different from traffic-induced vibration?
-
2.Do I really need a baseline survey before work starts?
-
3. Why do I need both AWA6257A and a general vibration meter on site?
-
4.Which calibrator should I use — ACE5003 or AWA6071A?
Not sure which instrument fits your site?
We look forward to hearing from you.
Tel: +86-19012832378