AWA6161A Acoustic Coupler (IEC60318-5)
AWA6161A Acoustic Coupler (IEC60318-5) AWA6161A Acoustic Coupler (IEC60318-5) AWA6161A Acoustic Coupler (IEC60318-5) AWA6161A Acoustic Coupler (IEC60318-5) AWA6161A Acoustic Coupler (IEC60318-5)
AWA6161A Acoustic Coupler (IEC60318-5)
Comply with standard IEC60318-5:2006
Applied to the model of earphone IP30 insert earphones, ER-3A insert earphone
Please select the operation you need
Aihua Instruments Aihua Instruments
Product Uses


An acoustic coupler for loading an earphone or hearing aid with a specified acoustic impedance when determining its physical performance characteristics, in the frequency range 125 Hz to 8 kHz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices


Technical Specifications

    Model

    AWA6160

    AWA6161A

    AWA6162

    AWA6163A

    Name

    Ear Simulator 

    Acoustic coupler (2 cc)

    Ear Simulator

    Acoustic coupler (6 cc)

    Fulfils Standard

    IEC 60318-1:2009

    IEC60318-5:2006

    IEC60318-4:2010

    IEC60318-3:2014

    Frequency Range

    20Hz~16,000Hz

    125 Hz~8,000 Hz

    20 Hz~10,000 Hz

    100 Hz~8,000 Hz

    Frequency Response

    ≤±1 dB

          ≤±0.5dB(200Hz~5,000Hz)

          ≤±1dB(125 Hz~8,000Hz)

    ≤ ±0.5dB(200Hz~5,000 Hz)

    ≤±1 dB(20 Hz~10,000 Hz)

     

    ≤ ±0.5dB(200Hz~5,000 Hz)

    ≤±1 dB(100 Hz~8,000 Hz)

     

    Used with Microphone

    Model AWA14426 (1/2 inch pressure field Microphone)


    Model AWA14422D (1/2 inch pressure field Microphone), also 1 inch pressure field Microphone


    Model AWA14424D (1/2 inch pressure field Microphone)

    Model AWA14412 (1 inch pressure field Microphone)

    Used with Preamplifier

    Model AWA14604 preamplifier (BNC) or AWA14601 preamplifier

    Operation Voltage Range for the Preamplifier

    12 V~36 V

    Length of cable

    2 m

    Uses

    The ear simulator for the measurement of supra-aural and circumaural earphones (used for example in audiometry and telephonometry) applied to the ear without acoustical leakage, in the frequency range from 20 Hz to 10 kHz. The same device can be used as an acoustic coupler at additional frequencies up to 16 kHz. 

    An acoustic coupler for loading an earphone or hearing aid with a specified acoustic impedance when determining its physical performance characteristics, in the frequency range 125 Hz to 8 kHz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices. 

    An occluded-ear simulator intended for the measurement of insert earphones in the frequency range from 100 Hz to 10 000 Hz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices. 

    An acoustic coupler for the measurement of supra-aural audiometric earphones in the frequency range from 125 Hz to 8 000 Hz. The acoustic coupler can be used as an objective and reproducible means of measuring the output of supra-aural earphones. It can be used for specifying reference equivalent threshold sound pressure levels for the calibration of audiometers. 

     

    Model of Earphone
    Radio Ear DD65V2 earphones, Sennheiser HDA280IP30 insert earphones, ER-3A insert earphoneIP30 insert earphones, ER-3A insert earphoneBeyer DT48 with flat cushion, Telephonic TDH39 with MX41/AR(or model 51) cushion, Telephonics TDH 49/50, Sennheiser HAD 280, RadioEar DD45