Sound Level Meter Calibration




Every reading a sound level meter produces is only as good as its last calibration. A stable, traceable acoustic calibrator is what turns a number on a screen into evidence you can stand behind.


contact us
  • 94 & 114 dB



    Standard dual-level output at 1000 Hz — checking the meter at two points confirms it's linear, not just accurate at one level

  • 2

    Times to calibrate every session — immediately before and immediately after the measurement, not just one or the other

A Reading Is Only as Trustworthy as Its Calibration

A sound level meter can drift out of tolerance from a knock, a battery change, humidity, or simple age — often with no visible sign that anything's wrong. The only way to know a reading is accurate is to check the meter against a known, stable reference immediately before and after it's used.

Every acoustic calibrator is built to a class under IEC 60942 — Class 1 or Class 2 — and as a rule, a calibrator should match or exceed the class of the meter it's checking. A Class 2 calibrator can't properly verify a Class 1 meter, but a Class 1 calibrator works for either.

Aihua's sound level calibrators cover the full range — from a fast, everyday field check to multi-frequency verification for a more thorough lab-level review.





Two Levels of Calibration Coverage

Typical Workflow Calibrating a Sound Level Meter

  • 1. Match the Class

    Confirm the calibrator's class meets or exceeds the meter being checked before relying on the result.

  • 2. Check Before

    Fit the calibrator to the microphone and confirm the meter reads the calibrator's reference level before starting.

  • 3. Measure

    Carry out the measurement session with the meter, without adjusting or removing the microphone in between.

  • 4. Check After

    Repeat the calibration check afterward — if the reading has drifted, the session's data needs to be flagged and reviewed.

Recommended Product 
All two are built to IEC 60942, with a dual-level 94 dB / 114 dB output at 1000 Hz for confirming linearity, not just a single point.

Compliance

Built Around the Standards Your Reports Reference

IEC 60942 Sound calibrators, Class 1 & Class 2
IEC 61672-1 Sound level meters
  •             Common Questions About Sound Level Meter Calibration

  • 1. Can I use a Class 2 calibrator on a Class 1 meter?

  • 2. Why does the calibrator output two levels — 94 dB and 114 dB?

  • 3. Do I need to calibrate before every measurement, or is once a day enough?

  • 4. What's the difference between a field check and a full recalibration?

    A field check with a calibrator takes a minute and confirms nothing has drifted since the last verified state. A full laboratory recalibration — typically every 1–2 years — is a more thorough process that issues a traceable certificate and can catch a gradual drift a quick field check wouldn't reveal.